Knowledge Base Menu

Electrically Controlled Exit Systems

Standard: EN 13637:2015

Standard Information

  • Standard Number: EN 13637:2015
  • Title: Building hardware - Electrically controlled exit systems for use on escape routes - Requirements and test methods
  • Status: Current
  • Application: Electrically controlled emergency exit systems

Scope and Application

EN 13637:2015 applies to electrically controlled exit systems that:

  • Are used on escape routes
  • Are electrically controlled
  • Can be operated manually in case of power failure
  • Are suitable for use in normal ambient temperatures
  • Are commonly used in commercial and public buildings
  • Integrate with access control systems

Classification System

The standard defines several classification categories:

  • Type: Push pad (P) or Lever handle (L)
  • Category: Single action (SA) or Double action (DA)
  • Durability: Grade 1 (10,000 cycles) or Grade 2 (50,000 cycles)
  • Corrosion resistance: Class 0 (no requirement) to Class 5 (highest)
  • Fire resistance: Fire resistant (FR) or Non-fire resistant (NFR)
  • Power supply: Mains powered (MP) or Battery powered (BP)
  • Backup power: With backup (WB) or Without backup (NB)

Performance Requirements

Devices must meet specific criteria for:

  • Operating force requirements (maximum 70N)
  • Operating movement (maximum 30mm)
  • Durability cycles
  • Corrosion resistance
  • Fire resistance (if applicable)
  • Mechanical strength
  • Safety requirements
  • Electrical safety
  • Power failure handling
  • Backup power performance
  • Access control integration

Testing Requirements

Testing procedures include:

  • Initial type testing (ITT)
  • Factory production control (FPC)
  • Durability testing
  • Corrosion resistance testing
  • Fire resistance testing (if applicable)
  • Mechanical strength testing
  • Safety testing
  • Electrical safety testing
  • Power failure testing
  • Backup power testing
  • Access control integration testing

Installation Requirements

Critical installation factors include:

  • Proper mounting height (900-1100mm from floor)
  • Correct alignment
  • Appropriate fixing methods
  • Clear signage requirements
  • Maintenance access
  • Emergency lighting integration
  • Accessibility requirements
  • Power supply requirements
  • Backup power installation
  • Access control system integration

Maintenance Guidelines

Regular maintenance should include:

  • Visual inspection
  • Operational testing
  • Lubrication of moving parts
  • Check of fixing points
  • Verification of signage
  • Emergency lighting check
  • Accessibility verification
  • Power supply testing
  • Backup power testing
  • Access control system testing

Application Guidelines

Recommended applications by building type:

  • Office Buildings: Grade 2, Class 3 corrosion resistance, Mains powered with backup
  • Retail Spaces: Grade 2, Class 4 corrosion resistance, Mains powered with backup
  • Healthcare Facilities: Grade 2, Class 4 corrosion resistance, Mains powered with backup, FR
  • Educational Buildings: Grade 2, Class 4 corrosion resistance, Mains powered with backup
  • Industrial Facilities: Grade 2, Class 5 corrosion resistance, Mains powered with backup

Safety Considerations

  • Clear emergency exit signage
  • Unobstructed access
  • Regular evacuation drills
  • Staff training requirements
  • Emergency lighting integration
  • Maintenance records
  • Accessibility compliance
  • Power failure procedures
  • Backup power maintenance
  • Access control system security

Important Considerations:

  • Select appropriate grade and class for intended use
  • Consider environmental conditions
  • Verify certification documentation
  • Ensure proper installation
  • Maintain regular inspection schedule
  • Follow manufacturer maintenance guidelines
  • Keep records of all maintenance activities
  • Consider accessibility requirements
  • Plan for power failure scenarios
  • Implement backup power procedures
  • Ensure access control system reliability