Knowledge Base Menu

Fire Rated Doors vs Fire Escape Doors

Understanding the Key Differences

While both fire rated doors and fire escape doors are crucial components of building fire safety, they serve different purposes and have distinct requirements. Understanding these differences is essential for proper implementation and compliance.

Fire Rated Security Door

View Our Fire Rated Security Doors

Explore our range of fire rated and fire escape security doors with EI30s-EI60s fire resistance ratings.

Overview

While both fire rated doors and fire escape doors are crucial components of building fire safety, they serve different purposes and have distinct requirements. Understanding these differences is essential for proper implementation and compliance.

Primary Purpose

Fire Rated Doors

  • Prevent fire spread between compartments
  • Protect escape routes
  • Maintain structural integrity
  • Contain smoke and heat
  • Protect property and assets

Fire Escape Doors

  • Provide safe exit routes
  • Ensure quick evacuation
  • Connect to external escape routes
  • Access emergency staircases
  • Link to assembly points

Technical Requirements

Fire Rated Doors

  • Fire resistance rating (30-240 minutes)
  • Smoke sealing requirements
  • Self-closing mechanism
  • Intumescent seals
  • Cold smoke seals
  • Frame compatibility
  • Hardware compatibility

Fire Escape Doors

  • Panic hardware (EN 1125/EN 179)
  • Single-action operation
  • Clear signage requirements
  • Emergency lighting
  • Accessibility requirements
  • Width requirements
  • Direction of opening

Location and Application

Fire Rated Doors

  • Internal compartment walls
  • Staircase enclosures
  • Corridor walls
  • Service risers
  • Plant rooms
  • Storage areas

Fire Escape Doors

  • Final exit doors
  • Staircase access points
  • External escape routes
  • Assembly point access
  • Emergency exits
  • Alternative escape routes

Operational Requirements

Fire Rated Doors

  • Must remain closed
  • Self-closing mechanism
  • Hold-open devices allowed
  • Regular maintenance required
  • Inspection requirements
  • Documentation needed

Fire Escape Doors

  • Must be easily operable
  • No hold-open devices
  • Clear access required
  • Regular testing needed
  • Emergency lighting checks
  • Signage maintenance

Common Applications

Typical building scenarios where both types are required:

  • Office Buildings: Fire rated doors between offices and corridors, fire escape doors at stairwell exits
  • Hospitals: Fire rated doors in ward areas, fire escape doors at emergency exits
  • Schools: Fire rated doors in classroom corridors, fire escape doors at assembly points
  • Shopping Centers: Fire rated doors in service areas, fire escape doors at mall exits
  • Industrial Facilities: Fire rated doors in storage areas, fire escape doors at external exits

Important Note:

Understanding the differences between fire-rated and fire escape doors is crucial for proper fire safety implementation.